Uses of Class
com.irurueta.navigation.inertial.calibration.CalibrationException
Packages that use CalibrationException
Package
Description
Contains classes for accelerometer calibration.
Contains classes for gyroscope calibration.
Contains classes for magnetometer calibration.
-
Uses of CalibrationException in com.irurueta.navigation.inertial.calibration.accelerometer
Methods in com.irurueta.navigation.inertial.calibration.accelerometer that throw CalibrationExceptionModifier and TypeMethodDescriptionvoid
AccelerometerCalibrator.calibrate()
Estimates accelerometer calibration parameters containing scale factors and cross-coupling errors.void
BaseBiasGravityNormAccelerometerCalibrator.calibrate()
Estimates accelerometer calibration parameters containing scale factors and cross-coupling errors.void
BaseGravityNormAccelerometerCalibrator.calibrate()
Estimates accelerometer calibration parameters containing bias, scale factors and cross-coupling errors.void
KnownBiasAndFrameAccelerometerLinearLeastSquaresCalibrator.calibrate()
Estimates accelerometer calibration parameters containing scale factors and cross-coupling errors.void
KnownBiasAndFrameAccelerometerNonLinearLeastSquaresCalibrator.calibrate()
Estimates accelerometer calibration parameters containing bias, scale factors and cross-coupling errors.void
KnownFrameAccelerometerLinearLeastSquaresCalibrator.calibrate()
Estimates accelerometer calibration parameters containing bias, scale factors and cross-coupling errors.void
KnownFrameAccelerometerNonLinearLeastSquaresCalibrator.calibrate()
Estimates accelerometer calibration parameters containing bias, scale factors and cross-coupling errors.void
LMedSRobustKnownBiasAndFrameAccelerometerCalibrator.calibrate()
Estimates accelerometer calibration parameters containing scale factors and cross-coupling errors.void
LMedSRobustKnownBiasAndGravityNormAccelerometerCalibrator.calibrate()
Estimates accelerometer calibration parameters containing scale factors and cross-coupling errors.void
LMedSRobustKnownBiasAndPositionAccelerometerCalibrator.calibrate()
Estimates accelerometer calibration parameters containing scale factors and cross-coupling errors.void
LMedSRobustKnownFrameAccelerometerCalibrator.calibrate()
Estimates accelerometer calibration parameters containing bias, scale factors and cross-coupling errors.void
LMedSRobustKnownGravityNormAccelerometerCalibrator.calibrate()
Estimates accelerometer calibration parameters containing bias, scale factors and cross-coupling errors.void
LMedSRobustKnownPositionAccelerometerCalibrator.calibrate()
Estimates accelerometer calibration parameters containing bias, scale factors and cross-coupling errors.void
MSACRobustKnownBiasAndFrameAccelerometerCalibrator.calibrate()
Estimates accelerometer calibration parameters containing scale factors and cross-coupling errors.void
MSACRobustKnownBiasAndGravityNormAccelerometerCalibrator.calibrate()
Estimates accelerometer calibration parameters containing bias, scale factors and cross-coupling errors.void
MSACRobustKnownBiasAndPositionAccelerometerCalibrator.calibrate()
Estimates accelerometer calibration parameters containing scale factors and cross-coupling errors.void
MSACRobustKnownFrameAccelerometerCalibrator.calibrate()
Estimates accelerometer calibration parameters containing bias, scale factors and cross-coupling errors.void
MSACRobustKnownGravityNormAccelerometerCalibrator.calibrate()
Estimates accelerometer calibration parameters containing bias, scale factors and cross-coupling errors.void
MSACRobustKnownPositionAccelerometerCalibrator.calibrate()
Estimates accelerometer calibration parameters containing bias, scale factors and cross-coupling errors.void
PROMedSRobustKnownBiasAndFrameAccelerometerCalibrator.calibrate()
Estimates accelerometer calibration parameters containing scale factors and cross-coupling errors.void
PROMedSRobustKnownBiasAndGravityNormAccelerometerCalibrator.calibrate()
Estimates accelerometer calibration parameters containing scale factors and cross-coupling errors.void
PROMedSRobustKnownBiasAndPositionAccelerometerCalibrator.calibrate()
Estimates accelerometer calibration parameters containing scale factors and cross-coupling errors.void
PROMedSRobustKnownFrameAccelerometerCalibrator.calibrate()
Estimates accelerometer calibration parameters containing bias, scale factors and cross-coupling errors.void
PROMedSRobustKnownGravityNormAccelerometerCalibrator.calibrate()
Estimates accelerometer calibration parameters containing bias, scale factors and cross-coupling errors.void
PROMedSRobustKnownPositionAccelerometerCalibrator.calibrate()
Estimates accelerometer calibration parameters containing bias, scale factors and cross-coupling errors.void
PROSACRobustKnownBiasAndFrameAccelerometerCalibrator.calibrate()
Estimates accelerometer calibration parameters containing scale factors and cross-coupling errors.void
PROSACRobustKnownBiasAndGravityNormAccelerometerCalibrator.calibrate()
Estimates accelerometer calibration parameters scale factors and cross-coupling errors.void
PROSACRobustKnownBiasAndPositionAccelerometerCalibrator.calibrate()
Estimates accelerometer calibration parameters containing scale factors and cross-coupling errors.void
PROSACRobustKnownFrameAccelerometerCalibrator.calibrate()
Estimates accelerometer calibration parameters containing bias, scale factors and cross-coupling errors.void
PROSACRobustKnownGravityNormAccelerometerCalibrator.calibrate()
Estimates accelerometer calibration parameters containing bias, scale factors and cross-coupling errors.void
PROSACRobustKnownPositionAccelerometerCalibrator.calibrate()
Estimates accelerometer calibration parameters containing bias, scale factors and cross-coupling errors.void
RANSACRobustKnownBiasAndFrameAccelerometerCalibrator.calibrate()
Estimates accelerometer calibration parameters containing scale factors and cross-coupling errors.void
RANSACRobustKnownBiasAndGravityNormAccelerometerCalibrator.calibrate()
Estimates accelerometer calibration parameters containing scale factors and cross-coupling errors.void
RANSACRobustKnownBiasAndPositionAccelerometerCalibrator.calibrate()
Estimates accelerometer calibration parameters containing scale factors and cross-coupling errors.void
RANSACRobustKnownFrameAccelerometerCalibrator.calibrate()
Estimates accelerometer calibration parameters containing bias, scale factors and cross-coupling errors.void
RANSACRobustKnownGravityNormAccelerometerCalibrator.calibrate()
Estimates accelerometer calibration parameters containing bias, scale factors and cross-coupling errors.void
RANSACRobustKnownPositionAccelerometerCalibrator.calibrate()
Estimates accelerometer calibration parameters containing bias, scale factors and cross-coupling errors. -
Uses of CalibrationException in com.irurueta.navigation.inertial.calibration.gyroscope
Methods in com.irurueta.navigation.inertial.calibration.gyroscope that throw CalibrationExceptionModifier and TypeMethodDescriptionvoid
EasyGyroscopeCalibrator.calibrate()
Estimates gyroscope calibration parameters containing bias, scale factors, cross-coupling errors and G-dependent coupling.void
GyroscopeCalibrator.calibrate()
Estimates gyroscope calibration parameters containing bias, scale factors, cross-coupling errors and g-dependant cross biases.void
KnownBiasAndFrameGyroscopeLinearLeastSquaresCalibrator.calibrate()
Estimates gyroscope calibration parameters containing bias, scale factors, cross-coupling errors and g-dependant cross biases.void
KnownBiasAndFrameGyroscopeNonLinearLeastSquaresCalibrator.calibrate()
Estimates gyroscope calibration parameters containing bias, scale factors, cross-coupling errors and g-dependant cross biases.void
KnownBiasEasyGyroscopeCalibrator.calibrate()
Estimates gyroscope calibration parameters containing scale factors, cross-coupling errors and G-dependent coupling.void
KnownBiasTurntableGyroscopeCalibrator.calibrate()
Estimates gyroscope calibration parameters containing bias, scale factors, cross-coupling errors and G-dependent coupling.void
KnownFrameGyroscopeLinearLeastSquaresCalibrator.calibrate()
Estimates gyroscope calibration parameters containing bias, scale factors, cross-coupling errors and g-dependant cross biases.void
KnownFrameGyroscopeNonLinearLeastSquaresCalibrator.calibrate()
Estimates gyroscope calibration parameters containing bias, scale factors, cross-coupling errors and G-dependent coupling.void
LMedSRobustEasyGyroscopeCalibrator.calibrate()
Estimates gyroscope calibration parameters containing bias, scale factors, cross-coupling errors and G-dependent coupling.void
LMedSRobustKnownBiasAndFrameGyroscopeCalibrator.calibrate()
Estimates gyroscope calibration parameters containing bias, scale factors cross-coupling errors and g-dependant cross biases.void
LMedSRobustKnownBiasEasyGyroscopeCalibrator.calibrate()
Estimates gyroscope calibration parameters containing scale factors, cross-coupling errors and G-dependent coupling.void
LMedSRobustKnownBiasTurntableGyroscopeCalibrator.calibrate()
Estimates gyroscope calibration parameters containing scale factors cross-coupling errors and g-dependant cross biases.void
LMedSRobustKnownFrameGyroscopeCalibrator.calibrate()
Estimates accelerometer calibration parameters containing bias, scale factors and cross-coupling errors.void
LMedSRobustTurntableGyroscopeCalibrator.calibrate()
Estimates gyroscope calibration parameters containing bias, scale factors cross-coupling errors and g-dependant cross biases.void
MSACRobustEasyGyroscopeCalibrator.calibrate()
Estimates gyroscope calibration parameters containing bias, scale factors, cross-coupling errors and G-dependent coupling.void
MSACRobustKnownBiasAndFrameGyroscopeCalibrator.calibrate()
Estimates gyroscope calibration parameters containing bias, scale factors cross-coupling errors and g-dependant cross biases.void
MSACRobustKnownBiasEasyGyroscopeCalibrator.calibrate()
Estimates gyroscope calibration parameters containing scale factors, cross-coupling errors and G-dependent coupling.void
MSACRobustKnownBiasTurntableGyroscopeCalibrator.calibrate()
Estimates gyroscope calibration parameters containing scale factors cross-coupling errors and g-dependant cross biases.void
MSACRobustKnownFrameGyroscopeCalibrator.calibrate()
Estimates gyroscope calibration parameters containing bias, scale factors cross-coupling errors and g-dependant cross biases.void
MSACRobustTurntableGyroscopeCalibrator.calibrate()
Estimates gyroscope calibration parameters containing bias, scale factors cross-coupling errors and g-dependant cross biases.void
PROMedSRobustEasyGyroscopeCalibrator.calibrate()
Estimates gyroscope calibration parameters containing bias, scale factors, cross-coupling errors and G-dependent coupling.void
PROMedSRobustKnownBiasAndFrameGyroscopeCalibrator.calibrate()
Estimates gyroscope calibration parameters containing bias, scale factors cross-coupling errors and g-dependant cross biases.void
PROMedSRobustKnownBiasEasyGyroscopeCalibrator.calibrate()
Estimates gyroscope calibration parameters containing scale factors, cross-coupling errors and G-dependent coupling.void
PROMedSRobustKnownBiasTurntableGyroscopeCalibrator.calibrate()
Estimates gyroscope calibration parameters containing scale factors cross-coupling errors and g-dependant cross biases.void
PROMedSRobustKnownFrameGyroscopeCalibrator.calibrate()
Estimates accelerometer calibration parameters containing bias, scale factors and cross-coupling errors.void
PROMedSRobustTurntableGyroscopeCalibrator.calibrate()
Estimates gyroscope calibration parameters containing bias, scale factors cross-coupling errors and g-dependant cross biases.void
PROSACRobustEasyGyroscopeCalibrator.calibrate()
Estimates gyroscope calibration parameters containing bias, scale factors, cross-coupling errors and G-dependent coupling.void
PROSACRobustKnownBiasAndFrameGyroscopeCalibrator.calibrate()
Estimates gyroscope calibration parameters containing bias, scale factors cross-coupling errors and g-dependant cross biases.void
PROSACRobustKnownBiasEasyGyroscopeCalibrator.calibrate()
Estimates gyroscope calibration parameters containing scale factors, cross-coupling errors and G-dependent coupling.void
PROSACRobustKnownBiasTurntableGyroscopeCalibrator.calibrate()
Estimates gyroscope calibration parameters containing scale factors cross-coupling errors and g-dependant cross biases.void
PROSACRobustKnownFrameGyroscopeCalibrator.calibrate()
Estimates gyroscope calibration parameters containing bias, scale factors cross-coupling errors and g-dependant cross biases.void
PROSACRobustTurntableGyroscopeCalibrator.calibrate()
Estimates gyroscope calibration parameters containing bias, scale factors cross-coupling errors and g-dependant cross biases.void
RANSACRobustEasyGyroscopeCalibrator.calibrate()
Estimates gyroscope calibration parameters containing bias, scale factors, cross-coupling errors and G-dependent coupling.void
RANSACRobustKnownBiasAndFrameGyroscopeCalibrator.calibrate()
Estimates gyroscope calibration parameters containing bias, scale factors cross-coupling errors and g-dependant cross biases.void
RANSACRobustKnownBiasEasyGyroscopeCalibrator.calibrate()
Estimates gyroscope calibration parameters containing scale factors, cross-coupling errors and G-dependent coupling.void
RANSACRobustKnownBiasTurntableGyroscopeCalibrator.calibrate()
Estimates gyroscope calibration parameters containing scale factors cross-coupling errors and g-dependant cross biases.void
RANSACRobustKnownFrameGyroscopeCalibrator.calibrate()
Estimates gyroscope calibration parameters containing bias, scale factors cross-coupling errors and g-dependant cross biases.void
RANSACRobustTurntableGyroscopeCalibrator.calibrate()
Estimates gyroscope calibration parameters containing bias, scale factors cross-coupling errors and g-dependant cross biases.void
TurntableGyroscopeCalibrator.calibrate()
Estimates gyroscope calibration parameters containing bias, scale factors, cross-coupling errors and G-dependent coupling. -
Uses of CalibrationException in com.irurueta.navigation.inertial.calibration.magnetometer
Methods in com.irurueta.navigation.inertial.calibration.magnetometer that throw CalibrationExceptionModifier and TypeMethodDescriptionvoid
BaseKnownHardIronMagneticFluxDensityNormMagnetometerCalibrator.calibrate()
Estimates magnetometer calibration parameters containing scale factors and cross-coupling errors.void
BaseMagneticFluxDensityNormMagnetometerCalibrator.calibrate()
Estimates magnetometer calibration parameters containing scale factors and cross-coupling errors.void
KnownFrameMagnetometerLinearLeastSquaresCalibrator.calibrate()
Estimates accelerometer calibration parameters containing scale factors and cross-coupling errors.void
KnownFrameMagnetometerNonLinearLeastSquaresCalibrator.calibrate()
Estimates magnetometer calibration parameters containing scale factors and cross-coupling errors.void
KnownHardIronAndFrameMagnetometerLinearLeastSquaresCalibrator.calibrate()
Estimates magnetometer calibration parameters containing scale factors and cross-coupling errors.void
KnownHardIronAndFrameMagnetometerNonLinearLeastSquaresCalibrator.calibrate()
Estimates magnetometer calibration parameters containing scale factors and cross-coupling errors.void
LMedSRobustKnownFrameMagnetometerCalibrator.calibrate()
Estimates magnetometer calibration parameters containing hard-iron bias and soft-iron scale factors and cross-coupling errors.void
LMedSRobustKnownHardIronAndFrameMagnetometerCalibrator.calibrate()
Estimates magnetometer calibration parameters containing soft-iron scale factors and cross-coupling errors.void
LMedSRobustKnownHardIronMagneticFluxDensityNormMagnetometerCalibrator.calibrate()
Estimates magnetometer calibration parameters containing hard-iron bias and soft-iron scale factors and cross-coupling errors.void
LMedSRobustKnownHardIronPositionAndInstantMagnetometerCalibrator.calibrate()
Estimates magnetometer calibration parameters containing soft-iron scale factors and cross-coupling errors.void
LMedSRobustKnownMagneticFluxDensityNormMagnetometerCalibrator.calibrate()
Estimates magnetometer calibration parameters containing hard-iron bias and soft-iron scale factors and cross-coupling errors.void
LMedSRobustKnownPositionAndInstantMagnetometerCalibrator.calibrate()
Estimates magnetometer calibration parameters containing hard-iron bias and soft-iron scale factors and cross-coupling errors.void
MagnetometerCalibrator.calibrate()
Estimates accelerometer calibration parameters containing scale factors and cross-coupling errors.void
MSACRobustKnownFrameMagnetometerCalibrator.calibrate()
Estimates magnetometer calibration parameters containing hard-iron bias and soft-iron scale factors and cross-coupling errors.void
MSACRobustKnownHardIronAndFrameMagnetometerCalibrator.calibrate()
Estimates magnetometer calibration parameters containing soft-iron scale factors and cross-coupling errors.void
MSACRobustKnownHardIronMagneticFluxDensityNormMagnetometerCalibrator.calibrate()
Estimates magnetometer calibration parameters containing hard-iron bias and soft-iron scale factors and cross-coupling errors.void
MSACRobustKnownHardIronPositionAndInstantMagnetometerCalibrator.calibrate()
Estimates magnetometer calibration parameters containing soft-iron scale factors and cross-coupling errors.void
MSACRobustKnownMagneticFluxDensityNormMagnetometerCalibrator.calibrate()
Estimates magnetometer calibration parameters containing hard-iron bias and soft-iron scale factors and cross-coupling errors.void
MSACRobustKnownPositionAndInstantMagnetometerCalibrator.calibrate()
Estimates magnetometer calibration parameters containing hard-iron bias and soft-iron scale factors and cross-coupling errors.void
PROMedSRobustKnownFrameMagnetometerCalibrator.calibrate()
Estimates magnetometer calibration parameters containing hard-iron bias and soft-iron scale factors and cross-coupling errors.void
PROMedSRobustKnownHardIronAndFrameMagnetometerCalibrator.calibrate()
Estimates magnetometer calibration parameters containing soft-iron scale factors and cross-coupling errors.void
PROMedSRobustKnownHardIronMagneticFluxDensityNormMagnetometerCalibrator.calibrate()
Estimates magnetometer calibration parameters containing hard-iron bias and soft-iron scale factors and cross-coupling errors.void
PROMedSRobustKnownHardIronPositionAndInstantMagnetometerCalibrator.calibrate()
Estimates magnetometer calibration parameters containing soft-iron scale factors and cross-coupling errors.void
PROMedSRobustKnownMagneticFluxDensityNormMagnetometerCalibrator.calibrate()
Estimates magnetometer calibration parameters containing hard-iron bias and soft-iron scale factors and cross-coupling errors.void
PROMedSRobustKnownPositionAndInstantMagnetometerCalibrator.calibrate()
Estimates magnetometer calibration parameters containing hard-iron bias and soft-iron scale factors and cross-coupling errors.void
PROSACRobustKnownFrameMagnetometerCalibrator.calibrate()
Estimates magnetometer calibration parameters containing hard-iron bias and soft-iron scale factors and cross-coupling errors.void
PROSACRobustKnownHardIronAndFrameMagnetometerCalibrator.calibrate()
Estimates magnetometer calibration parameters containing soft-iron scale factors and cross-coupling errors.void
PROSACRobustKnownHardIronMagneticFluxDensityNormMagnetometerCalibrator.calibrate()
Estimates magnetometer calibration parameters containing hard-iron bias and soft-iron scale factors and cross-coupling errors.void
PROSACRobustKnownHardIronPositionAndInstantMagnetometerCalibrator.calibrate()
Estimates magnetometer calibration parameters containing soft-iron scale factors and cross-coupling errors.void
PROSACRobustKnownMagneticFluxDensityNormMagnetometerCalibrator.calibrate()
Estimates magnetometer calibration parameters containing hard-iron bias and soft-iron scale factors and cross-coupling errors.void
PROSACRobustKnownPositionAndInstantMagnetometerCalibrator.calibrate()
Estimates magnetometer calibration parameters containing hard-iron bias and soft-iron scale factors and cross-coupling errors.void
RANSACRobustKnownFrameMagnetometerCalibrator.calibrate()
Estimates magnetometer calibration parameters containing hard-iron bias and soft-iron scale factors and cross-coupling errors.void
RANSACRobustKnownHardIronAndFrameMagnetometerCalibrator.calibrate()
Estimates magnetometer calibration parameters containing soft-iron scale factors and cross-coupling errors.void
RANSACRobustKnownHardIronMagneticFluxDensityNormMagnetometerCalibrator.calibrate()
Estimates magnetometer calibration parameters containing hard-iron bias and soft-iron scale factors and cross-coupling errors.void
RANSACRobustKnownHardIronPositionAndInstantMagnetometerCalibrator.calibrate()
Estimates magnetometer calibration parameters containing soft-iron scale factors and cross-coupling errors.void
RANSACRobustKnownMagneticFluxDensityNormMagnetometerCalibrator.calibrate()
Estimates magnetometer calibration parameters containing hard-iron bias and soft-iron scale factors and cross-coupling errors.void
RANSACRobustKnownPositionAndInstantMagnetometerCalibrator.calibrate()
Estimates magnetometer calibration parameters containing hard-iron bias and soft-iron scale factors and cross-coupling errors.private void
KnownHardIronPositionAndInstantMagnetometerCalibrator.computeGroundTruthMagneticFluxDensityNorm()
Computes expected ground truth magnetic flux density norm based on World Magnetic Model.private void
KnownPositionAndInstantMagnetometerCalibrator.computeGroundTruthMagneticFluxDensityNorm()
Computes expected ground truth magnetic flux density norm based on World Magnetic Model.protected void
BaseKnownHardIronMagneticFluxDensityNormMagnetometerCalibrator.onBeforeCalibrate()
Called before calibration occurs.protected void
BaseMagneticFluxDensityNormMagnetometerCalibrator.onBeforeCalibrate()
Called before calibration occurs.protected void
KnownHardIronPositionAndInstantMagnetometerCalibrator.onBeforeCalibrate()
Called before calibration occurs.protected void
KnownPositionAndInstantMagnetometerCalibrator.onBeforeCalibrate()
Called before calibration occurs.