Class PROMedSRobustKnownFrameAccelerometerCalibrator

java.lang.Object
com.irurueta.navigation.inertial.calibration.accelerometer.RobustKnownFrameAccelerometerCalibrator
com.irurueta.navigation.inertial.calibration.accelerometer.PROMedSRobustKnownFrameAccelerometerCalibrator
All Implemented Interfaces:
AccelerometerCalibrator, AccelerometerNonLinearCalibrator, OrderedStandardDeviationFrameBodyKinematicsAccelerometerCalibrator, QualityScoredAccelerometerCalibrator, UnknownBiasAccelerometerCalibrator, UnknownBiasNonLinearAccelerometerCalibrator, AccelerometerBiasUncertaintySource, AccelerometerCalibrationSource

public class PROMedSRobustKnownFrameAccelerometerCalibrator extends RobustKnownFrameAccelerometerCalibrator
Robustly estimates accelerometer biases, cross couplings and scaling factors using an PROMedS algorithm to discard outliers.

To use this calibrator at least 4 measurements at different known frames must be provided. In other words, accelerometer samples must be obtained at 4 different positions, orientations and velocities (although typically velocities are always zero).

Measured specific force is assumed to follow the model shown below:

     fmeas = ba + (I + Ma) * ftrue + w
 
Where: - fmeas is the measured specific force. This is a 3x1 vector. - ba is accelerometer bias. Ideally, on a perfect accelerometer, this should be a 3x1 zero vector. - I is the 3x3 identity matrix. - Ma is the 3x3 matrix containing cross-couplings and scaling factors. Ideally, on a perfect accelerometer, this should be a 3x3 zero matrix. - ftrue is ground-truth specific force. - w is measurement noise.
  • Field Details

    • DEFAULT_STOP_THRESHOLD

      public static final double DEFAULT_STOP_THRESHOLD
      Default value to be used for stop threshold. Stop threshold can be used to avoid keeping the algorithm unnecessarily iterating in case that best estimated threshold using median of residuals is not small enough. Once a solution is found that generates a threshold below this value, the algorithm will stop. The stop threshold can be used to prevent the LMedS algorithm iterating too many times in cases where samples have a very similar accuracy. For instance, in cases where proportion of outliers is very small (close to 0%), and samples are very accurate (i.e. 1e-6), the algorithm would iterate for a long time trying to find the best solution when indeed there is no need to do that if a reasonable threshold has already been reached. Because of this behaviour the stop threshold can be set to a value much lower than the one typically used in RANSAC, and yet the algorithm could still produce even smaller thresholds in estimated results.
      See Also:
    • MIN_STOP_THRESHOLD

      public static final double MIN_STOP_THRESHOLD
      Minimum allowed stop threshold value.
      See Also:
    • stopThreshold

      private double stopThreshold
      Threshold to be used to keep the algorithm iterating in case that best estimated threshold using median of residuals is not small enough. Once a solution is found that generates a threshold below this value, the algorithm will stop. The stop threshold can be used to prevent the LMedS algorithm iterating too many times in cases where samples have a very similar accuracy. For instance, in cases where proportion of outliers is very small (close to 0%), and samples are very accurate (i.e. 1e-6), the algorithm would iterate for a long time trying to find the best solution when indeed there is no need to do that if a reasonable threshold has already been reached. Because of this behaviour the stop threshold can be set to a value much lower than the one typically used in RANSAC, and yet the algorithm could still produce even smaller thresholds in estimated results.
    • qualityScores

      private double[] qualityScores
      Quality scores corresponding to each provided sample. The larger the score value the better the quality of the sample.
  • Constructor Details

    • PROMedSRobustKnownFrameAccelerometerCalibrator

      public PROMedSRobustKnownFrameAccelerometerCalibrator()
      Constructor.
    • PROMedSRobustKnownFrameAccelerometerCalibrator

      public PROMedSRobustKnownFrameAccelerometerCalibrator(RobustKnownFrameAccelerometerCalibratorListener listener)
      Constructor.
      Parameters:
      listener - listener to be notified of events such as when estimation starts, ends or its progress significantly changes.
    • PROMedSRobustKnownFrameAccelerometerCalibrator

      public PROMedSRobustKnownFrameAccelerometerCalibrator(List<StandardDeviationFrameBodyKinematics> measurements)
      Constructor.
      Parameters:
      measurements - list of body kinematics measurements with standard deviations taken at different frames (positions, orientations and velocities).
    • PROMedSRobustKnownFrameAccelerometerCalibrator

      public PROMedSRobustKnownFrameAccelerometerCalibrator(List<StandardDeviationFrameBodyKinematics> measurements, RobustKnownFrameAccelerometerCalibratorListener listener)
      Constructor.
      Parameters:
      measurements - list of body kinematics measurements with standard deviations taken at different frames (positions, orientations and velocities).
      listener - listener to handle events raised by this calibrator.
    • PROMedSRobustKnownFrameAccelerometerCalibrator

      public PROMedSRobustKnownFrameAccelerometerCalibrator(boolean commonAxisUsed)
      Constructor.
      Parameters:
      commonAxisUsed - indicates whether z-axis is assumed to be common for accelerometer and gyroscope.
    • PROMedSRobustKnownFrameAccelerometerCalibrator

      public PROMedSRobustKnownFrameAccelerometerCalibrator(boolean commonAxisUsed, RobustKnownFrameAccelerometerCalibratorListener listener)
      Constructor.
      Parameters:
      commonAxisUsed - indicates whether z-axis is assumed to be common for accelerometer and gyroscope.
      listener - listener to handle events raised by this calibrator.
    • PROMedSRobustKnownFrameAccelerometerCalibrator

      public PROMedSRobustKnownFrameAccelerometerCalibrator(List<StandardDeviationFrameBodyKinematics> measurements, boolean commonAxisUsed)
      Constructor.
      Parameters:
      measurements - list of body kinematics measurements with standard deviations taken at different frames (positions, orientations and velocities).
      commonAxisUsed - indicates whether z-axis is assumed to be common for accelerometer and gyroscope.
    • PROMedSRobustKnownFrameAccelerometerCalibrator

      public PROMedSRobustKnownFrameAccelerometerCalibrator(List<StandardDeviationFrameBodyKinematics> measurements, boolean commonAxisUsed, RobustKnownFrameAccelerometerCalibratorListener listener)
      Constructor.
      Parameters:
      measurements - list of body kinematics measurements with standard deviations taken at different frames (positions, orientations and velocities).
      commonAxisUsed - indicates whether z-axis is assumed to be common for accelerometer and gyroscope.
      listener - listener to handle events raised by this calibrator.
    • PROMedSRobustKnownFrameAccelerometerCalibrator

      public PROMedSRobustKnownFrameAccelerometerCalibrator(double[] qualityScores)
      Constructor.
      Parameters:
      qualityScores - quality scores corresponding to each provided measurement. The larger the score value the better the quality of the sample.
      Throws:
      IllegalArgumentException - if provided quality scores length is smaller than 4 samples.
    • PROMedSRobustKnownFrameAccelerometerCalibrator

      public PROMedSRobustKnownFrameAccelerometerCalibrator(double[] qualityScores, RobustKnownFrameAccelerometerCalibratorListener listener)
      Constructor.
      Parameters:
      qualityScores - quality scores corresponding to each provided measurement. The larger the score value the better the quality of the sample.
      listener - listener to be notified of events such as when estimation starts, ends or its progress significantly changes.
      Throws:
      IllegalArgumentException - if provided quality scores length is smaller than 4 samples.
    • PROMedSRobustKnownFrameAccelerometerCalibrator

      public PROMedSRobustKnownFrameAccelerometerCalibrator(double[] qualityScores, List<StandardDeviationFrameBodyKinematics> measurements)
      Constructor.
      Parameters:
      qualityScores - quality scores corresponding to each provided measurement. The larger the score value the better the quality of the sample.
      measurements - list of body kinematics measurements with standard deviations taken at different frames (positions, orientations and velocities).
      Throws:
      IllegalArgumentException - if provided quality scores length is smaller than 4 samples.
    • PROMedSRobustKnownFrameAccelerometerCalibrator

      public PROMedSRobustKnownFrameAccelerometerCalibrator(double[] qualityScores, List<StandardDeviationFrameBodyKinematics> measurements, RobustKnownFrameAccelerometerCalibratorListener listener)
      Constructor.
      Parameters:
      qualityScores - quality scores corresponding to each provided measurement. The larger the score value the better the quality of the sample.
      measurements - list of body kinematics measurements with standard deviations taken at different frames (positions, orientations and velocities).
      listener - listener to handle events raised by this calibrator.
      Throws:
      IllegalArgumentException - if provided quality scores length is smaller than 4 samples.
    • PROMedSRobustKnownFrameAccelerometerCalibrator

      public PROMedSRobustKnownFrameAccelerometerCalibrator(double[] qualityScores, boolean commonAxisUsed)
      Constructor.
      Parameters:
      qualityScores - quality scores corresponding to each provided measurement. The larger the score value the better the quality of the sample.
      commonAxisUsed - indicates whether z-axis is assumed to be common for accelerometer and gyroscope.
      Throws:
      IllegalArgumentException - if provided quality scores length is smaller than 4 samples.
    • PROMedSRobustKnownFrameAccelerometerCalibrator

      public PROMedSRobustKnownFrameAccelerometerCalibrator(double[] qualityScores, boolean commonAxisUsed, RobustKnownFrameAccelerometerCalibratorListener listener)
      Constructor.
      Parameters:
      qualityScores - quality scores corresponding to each provided measurement. The larger the score value the better the quality of the sample.
      commonAxisUsed - indicates whether z-axis is assumed to be common for accelerometer and gyroscope.
      listener - listener to handle events raised by this calibrator.
      Throws:
      IllegalArgumentException - if provided quality scores length is smaller than 4 samples.
    • PROMedSRobustKnownFrameAccelerometerCalibrator

      public PROMedSRobustKnownFrameAccelerometerCalibrator(double[] qualityScores, List<StandardDeviationFrameBodyKinematics> measurements, boolean commonAxisUsed)
      Constructor.
      Parameters:
      qualityScores - quality scores corresponding to each provided measurement. The larger the score value the better the quality of the sample.
      measurements - list of body kinematics measurements with standard deviations taken at different frames (positions, orientations and velocities).
      commonAxisUsed - indicates whether z-axis is assumed to be common for accelerometer and gyroscope.
      Throws:
      IllegalArgumentException - if provided quality scores length is smaller than 4 samples.
    • PROMedSRobustKnownFrameAccelerometerCalibrator

      public PROMedSRobustKnownFrameAccelerometerCalibrator(double[] qualityScores, List<StandardDeviationFrameBodyKinematics> measurements, boolean commonAxisUsed, RobustKnownFrameAccelerometerCalibratorListener listener)
      Constructor.
      Parameters:
      qualityScores - quality scores corresponding to each provided measurement. The larger the score value the better the quality of the sample.
      measurements - list of body kinematics measurements with standard deviations taken at different frames (positions, orientations and velocities).
      commonAxisUsed - indicates whether z-axis is assumed to be common for accelerometer and gyroscope.
      listener - listener to handle events raised by this calibrator.
      Throws:
      IllegalArgumentException - if provided quality scores length is smaller than 4 samples.
  • Method Details

    • getStopThreshold

      public double getStopThreshold()
      Returns threshold to be used to keep the algorithm iterating in case that best estimated threshold using median of residuals is not small enough. Once a solution is found that generates a threshold below this value, the algorithm will stop. The stop threshold can be used to prevent the LMedS algorithm to iterate too many times in cases where samples have a very similar accuracy. For instance, in cases where proportion of outliers is very small (close to 0%), and samples are very accurate (i.e. 1e-6), the algorithm would iterate for a long time trying to find the best solution when indeed there is no need to do that if a reasonable threshold has already been reached. Because of this behaviour the stop threshold can be set to a value much lower than the one typically used in RANSAC, and yet the algorithm could still produce even smaller thresholds in estimated results.
      Returns:
      stop threshold to stop the algorithm prematurely when a certain accuracy has been reached.
    • setStopThreshold

      public void setStopThreshold(double stopThreshold) throws com.irurueta.navigation.LockedException
      Sets threshold to be used to keep the algorithm iterating in case that best estimated threshold using median of residuals is not small enough. Once a solution is found that generates a threshold below this value, the algorithm will stop. The stop threshold can be used to prevent the LMedS algorithm to iterate too many times in cases where samples have a very similar accuracy. For instance, in cases where proportion of outliers is very small (close to 0%), and samples are very accurate (i.e. 1e-6), the algorithm would iterate for a long time trying to find the best solution when indeed there is no need to do that if a reasonable threshold has already been reached. Because of this behaviour the stop threshold can be set to a value much lower than the one typically used in RANSAC, and yet the algorithm could still produce even smaller thresholds in estimated results.
      Parameters:
      stopThreshold - stop threshold to stop the algorithm prematurely when a certain accuracy has been reached.
      Throws:
      IllegalArgumentException - if provided value is zero or negative.
      com.irurueta.navigation.LockedException - if calibrator is currently running.
    • getQualityScores

      public double[] getQualityScores()
      Returns quality scores corresponding to each provided sample. The larger the score value the better the quality of the sample.
      Specified by:
      getQualityScores in interface QualityScoredAccelerometerCalibrator
      Overrides:
      getQualityScores in class RobustKnownFrameAccelerometerCalibrator
      Returns:
      quality scores corresponding to each sample.
    • setQualityScores

      public void setQualityScores(double[] qualityScores) throws com.irurueta.navigation.LockedException
      Sets quality scores corresponding to each provided sample. The larger the score value the better the quality of the sample.
      Specified by:
      setQualityScores in interface QualityScoredAccelerometerCalibrator
      Overrides:
      setQualityScores in class RobustKnownFrameAccelerometerCalibrator
      Parameters:
      qualityScores - quality scores corresponding to each sample.
      Throws:
      IllegalArgumentException - if provided quality scores length is smaller than minimum required samples.
      com.irurueta.navigation.LockedException - if calibrator is currently running.
    • isReady

      public boolean isReady()
      Indicates whether solver is ready to find a solution.
      Specified by:
      isReady in interface AccelerometerCalibrator
      Overrides:
      isReady in class RobustKnownFrameAccelerometerCalibrator
      Returns:
      true if solver is ready, false otherwise.
    • calibrate

      public void calibrate() throws com.irurueta.navigation.LockedException, com.irurueta.navigation.NotReadyException, CalibrationException
      Estimates accelerometer calibration parameters containing bias, scale factors and cross-coupling errors.
      Throws:
      com.irurueta.navigation.LockedException - if calibrator is currently running.
      com.irurueta.navigation.NotReadyException - if calibrator is not ready.
      CalibrationException - if estimation fails for numerical reasons.
    • getMethod

      public com.irurueta.numerical.robust.RobustEstimatorMethod getMethod()
      Returns method being used for robust estimation.
      Specified by:
      getMethod in class RobustKnownFrameAccelerometerCalibrator
      Returns:
      method being used for robust estimation.
    • isQualityScoresRequired

      public boolean isQualityScoresRequired()
      Indicates whether this calibrator requires quality scores for each measurement or not.
      Returns:
      true if quality scores are required, false otherwise.
    • internalSetQualityScores

      private void internalSetQualityScores(double[] qualityScores)
      Sets quality scores corresponding to each provided sample. This method is used internally and does not check whether instance is locked or not.
      Parameters:
      qualityScores - quality scores to be set.
      Throws:
      IllegalArgumentException - if provided quality scores length is smaller than 3 samples.