Interface UnorderedStandardDeviationFrameBodyKinematicsAccelerometerCalibrator
- All Superinterfaces:
AccelerometerCalibrator
- All Known Implementing Classes:
KnownBiasAndFrameAccelerometerNonLinearLeastSquaresCalibrator
,KnownFrameAccelerometerNonLinearLeastSquaresCalibrator
public interface UnorderedStandardDeviationFrameBodyKinematicsAccelerometerCalibrator
extends AccelerometerCalibrator
Defines an accelerometer calibrator using unordered collections of
StandardDeviationFrameBodyKinematics
measurements.-
Method Summary
Modifier and TypeMethodDescriptionGets a collection of body kinematics measurements taken at different frames (positions, orientations and velocities) and containing the standard deviations of accelerometer and gyroscope measurements.void
setMeasurements
(Collection<? extends StandardDeviationFrameBodyKinematics> measurements) Sets a collection of body kinematics measurements taken at different frames (positions, orientations and velocities) and containing the standard deviations of accelerometer and gyroscope measurements.Methods inherited from interface com.irurueta.navigation.inertial.calibration.accelerometer.AccelerometerCalibrator
calibrate, getEstimatedMa, getEstimatedMxy, getEstimatedMxz, getEstimatedMyx, getEstimatedMyz, getEstimatedMzx, getEstimatedMzy, getEstimatedSx, getEstimatedSy, getEstimatedSz, getMeasurementType, getMinimumRequiredMeasurements, isCommonAxisUsed, isOrderedMeasurementsRequired, isQualityScoresRequired, isReady, isRunning, setCommonAxisUsed
-
Method Details
-
getMeasurements
Collection<StandardDeviationFrameBodyKinematics> getMeasurements()Gets a collection of body kinematics measurements taken at different frames (positions, orientations and velocities) and containing the standard deviations of accelerometer and gyroscope measurements. If a single device IMU needs to be calibrated, typically all measurements are taken at the same position, with zero velocity and multiple orientations. However, if we just want to calibrate the a given IMU model (e.g. obtain an average and less precise calibration for the IMU of a given phone model), we could take measurements collected throughout the planet at multiple positions while the phone remains static (e.g. while charging), hence each measurement position will change, velocity will remain zero and orientation will be typically constant at horizontal orientation while the phone remains on a flat surface.- Returns:
- a collection of body kinematics measurements taken at different frames (positions, orientations and velocities).
-
setMeasurements
void setMeasurements(Collection<? extends StandardDeviationFrameBodyKinematics> measurements) throws com.irurueta.navigation.LockedException Sets a collection of body kinematics measurements taken at different frames (positions, orientations and velocities) and containing the standard deviations of accelerometer and gyroscope measurements. If a single device IMU needs to be calibrated, typically all measurements are taken at the same position, with zero velocity and multiple orientations. However, if we just want to calibrate the a given IMU model (e.g. obtain an average and less precise calibration for the IMU of a given phone model), we could take measurements collected throughout the planet at multiple positions while the phone remains static (e.g. while charging), hence each measurement position will change, velocity will remain zero and orientation will be typically constant at horizontal orientation while the phone remains on a flat surface.- Parameters:
measurements
- collection of body kinematics measurements taken at different frames (positions, orientations and velocities).- Throws:
com.irurueta.navigation.LockedException
- if calibrator is currently running.
-